Data Collect
² Three-phase voltage/ /Three-phase current //Three-phase power factor
² Active power//Reactive power
² Frequency/ / harmonic voltage/ / harmonic electric current
² Daily voltage / / Maximum and minimum current
² Blackout moment / / Total blackout time
² Voltage ultra-cap, super-time minimum / / Lack of time
² Harmonic analysis 3-13 times, and the total harmonic distortion rate
² Keep data for three months
Data Telecommunications
1、Real-time monitoring
Three-phase voltage / /Three-phase current / / Three-phase power factor
Harmonic / / frequency / / Active Power / / Reactive power
Capacitors switch state / / Fault state
2、 Regular collection
l Total Data
l Actually point data
Three-phase voltage / / Three-phase current / / Three-phase power factor Three-phase active power / / Three-phase reactive power harmonic / / Frequency
Reactive Power Compensation
² Sample physical data is reactive power, without switching oscillation.
² Y-compensation, Δ- compensation, Y + Δ combination of compensation
² Circle switch, code switch, method is 111, 122, 123, 124
² Automatic and manual switching
Running Protective
☆ Cut off capacitor one by one when over-voltage, under-voltage and harmonic gauge
☆ Cut off capacitor rapidly and alarm when lack of phase
☆ Self-inspection function to ensure that each output circuit keep disconnecting power after connect the electric
☆ Data protection, record all data more than a year after cut off power
Data Manage
² Three-phase voltage / / Three-phase current / / Three-phase power factor and day Max numerical / /Min numerical appear moment
² Three phase active power factor / / Reactive power factor and day Max numeral / /Min numerical appear moment
² Harmonic / / Frequency and day Max numerical / / Min numerical appear moment
² Voltage \ current over limited / / limited time\
² Max current in 15 minutes
² Basic on Windows operate system, manually create all kinds of form, chart and draw
² Statistics power supply reliable rate and voltage passing rate
Technical parameters
1. Basic parameters
Voltage: AC 220V ± 20%
Power frequency: 50Hz ± 5%
Sampling voltage: AC 220V ± 20%
sampling current: 0 ~ 5A
Power: ≤ 15W
Sensitivity: 100mA
2. Telecommunications
Physical interface: RS232 / RS485
Telecommunications Statute: 101, CDT,
Polling baud rate: 1200bps, 2400bps, 4800bps, 9600bps optional.
3、Others
Performance: the DL/T721-2000
Anti-jamming performance: the GB/T15153.1-1998
Weight: 1.5Kg
Dimensions Size: 145 × 234 × 70
Embedded: 144 × 144 × 80 (open Hole Size: 138 mm × 138 mm) |